Graco ProMix 2KE

To Order Call:
216.749.5100216.749.5100

Available in pump and metered versions for all spray technologies, ProMix 2KE makes plural component finishing EASY. Designed for multi-color, two component, in-booth applications.

  • Designed for multi-color, two component, in-booth applications
  • Choose between pump-based or meter-based plural component systems
  • Stay on ratio within predefined tolerance limits, down to ±1% with the meter version and ±2% with the pump version
  • Off-ratio material will not reach your product – eliminating expensive re-work
  • Easy to service cartridge style fluid valves
  • Ability to program maintenance reminders

LCD Display

  • Mounts up to 10 feet away with standard cable
  • Simple operation functions: standby, spray, purge and flushing
  • Displays mix ratio, pot life time(s), and material flow rate
  • Easy to change colors on meter units
  • Material use screen for tracking costs and creating environmental reports
  • Settable maintenance reminders: pump cycles, valve cycles and filter days
  • ProMix 2KE Meter-Based System

    Maximum fluid working pressure

    3000 psi

    Maximum working air pressure

    100 psi

    Air supply

    75–100 psi

    Air filter inlet size

    3/8 npt(f)

    Air filtration for air logic (Graco-supplied)

    5 micron (minimum) filtration required; clean and dry air

    Air filtration for atomizing air (user-supplied)

    30 micron (minimum) filtration required; clean and dry air

    Mixing ratio range

    0.1:1–30.0:1

    On-ratio accuracy

    up to +/- 1%, user selectable

    Fluids handled

    one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes

    Fluid inlet sizes

    1/4 npt(f)

    Fluid outlet size (static mixer)

    1/4 npt(f)

    External power supply requirements

    85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge

    Operating temperature range

    41–122°F

    Approximate Weight

    200 lb

    Environmental conditions rating

    indoor use, pollution degree (2), installation category II

    Wetted parts

    303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE

    Fluid Flow Rate Range

    G3000, G250 Meter

    0.02–1.00 gpm

    G3000HR, G250HR Meter

    0.01–0.50 gpm

    Coriolis Meter

    0.005–1.00 gpm

    S3000 Solvent Meter (accessory)

    0.01–0.50 gpm

    Noise Level

    Sound pressure level

    below 70 dBA

    Sound power level

    below 85 dBA

    ProMix 2KE

    Maximum fluid working pressure

    See Manual 3A0868.

    Maximum working air pressure

    100 psi

    Air supply

    75 to 100 psi

    Air filter inlet size

    3/8 npt(f)

    Air filtration for air logic (Graco-supplied)

    5 micron (minimum) filtration required; clean and dry air

    Air filtration for atomizing air (user-supplied)

    30 micron (minimum) filtration required; clean and dry air

    Mixing ratio range

    0.1:1 to 30:1

    Viscosity range of fluid

    20 to 5000 cps

    Fluid filtration (user-supplied)

    100 mesh minimum

    Fluid outlet size (static mixer)

    1/4 npt(f)

    External power supply requirements

    85 – 250 Vac, 50/60 Hz, 2 amps maximum draw. 15 amp maximum circuit breaker required. 8 to 14 AWG power supply wire gauge

    Operating temperature range

    41° to 122°F

    Approximate weight

    300 lb

    Environmental conditions rating

    indoor use, pollution degree (2), installation category II

    Fluids handled

    one or two component:solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates

    On-ratio accuracy

    1:1 to 10:1 Mixing Ratio

    ± 2%

    10.1:1 to 30:1 Mixing Ratio

    ± 5%

    Noise level

    Sound pressure level

    below 70 dBA

    Sound power level

    Below 85 dBA

    Materials of construction

    Wetted materials on all models

    303, 304 SST; Tungsten carbide (with nickel binder);perfluoroelastomer; PTFE

    ProMix 2KE Pump-Based System

    Maximum fluid working pressure

    See the ProMix 2KE manual.

    Maximum working air pressure

    100 psi

    Air supply

    75–100 psi

    Air filter inlet size

    3/8 npt(f)

    Air filtration for air logic (Graco-supplied)

    5 micron (minimum) filtration required; clean and dry air

    Air filtration for atomizing air (user-supplied)

    30 micron (minimum) filtration required; clean and dry air

    Mixing ratio range

    0.1:1–30:1

    On-ratio accuracy

    1:1 to 10:1 Mixing Ratios: +/- 2%, 10:1 to 30:1 Mixing Ratios: +/- 5%

    Fluids handled

    one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates

    Viscosity range of fluid

    20–5000 cps

    Fluid filtration (user-supplied)

    100 mesh minimum

    Fluid outlet size (static mixer)

    1/4 npt(f)

    External power supply requirements

    85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge

    Operating temperature range

    41–122°F

    Approximate Weight

    300 lb

    Environmental conditions rating

    indoor use, pollution degree (2), installation category II

    Wetted parts

    303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE

    Noise Level

    Sound pressure level

    below 70 dBA

    Sound power level

    below 85 dBA

    ProMix® 2KE

    Maximum fluid working pressure

    See Hazardous Location Models in manual 3A0870

    Maximum working air pressure

    100 psi

    Air supply

    75 – 100 psi

    Air filter inlet size

    3/8 npt(f)

    Air filtration for air logic (Graco-supplied)

    5 micron (minimum) filtration required; clean and dry air

    Air filtration for atomizing air (user-supplied)

    30 micron (minimum) filtration required; clean and dry air

    Mixing ratio range

    0.1:1- 30:1

    On-ratio accuracy

    up to ±1%, user selectable

    Fluids handled

    one or two component:

    solvent and waterborne paints

    polyurethanes

    epoxies

    acid catalyzed varnishes

    moisture sensitive isocyanates

    Viscosity range of fluid

    20- 5000 cps

    Fluid filtration (user-supplied)

    100 mesh minimum

    Fluid flow rate range

    G3000, G250 Meter

    0.02-1.00 gal/min

    G3000HR, G250HR Meter

    0.01-0.50 gal/min

    Coriolis Meter

    0.005-1.00 gal/min

    S3000 Solvent Meter (accessory)

    0.01-0.50 gal/min

    Fluid inlet sizes

    Flow Meter

    1/4 npt(f)

    Dose Valve/Color Valve Adapters

    1/4 npt(f)

    Fluid outlet size (static mixer)

    1/4 npt(f)

    External Power Supply Requirements

    85 15 amp maximum circuit breaker required-

    250 Vac, 50/60 Hz, 2 amps maximum draw

    8 to 14 AWG power supply wire gauge

    Operating temperature range

    41- 122° F

    Approximate Weight

    Meter Systems

    200 lb

    Pump Systems

    300 lb

    Environmental Conditions Rating

    indoor use, pollution degree (2), installation category II

    Noise Level

    Sound pressure level

    below 70 dBA

    Sound power level

    below 85 dBA

    Wetted parts

    303, 304 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE