To Order Call:
216.749.5100216.749.5100
Available in pump and metered versions for all spray technologies, ProMix 2KE makes plural component finishing EASY. Designed for multi-color, two component, in-booth applications.
- Designed for multi-color, two component, in-booth applications
- Choose between pump-based or meter-based plural component systems
- Stay on ratio within predefined tolerance limits, down to ±1% with the meter version and ±2% with the pump version
- Off-ratio material will not reach your product – eliminating expensive re-work
- Easy to service cartridge style fluid valves
- Ability to program maintenance reminders
LCD Display
- Mounts up to 10 feet away with standard cable
- Simple operation functions: standby, spray, purge and flushing
- Displays mix ratio, pot life time(s), and material flow rate
- Easy to change colors on meter units
- Material use screen for tracking costs and creating environmental reports
- Settable maintenance reminders: pump cycles, valve cycles and filter days
-
ProMix 2KE Meter-Based System
Maximum fluid working pressure
3000 psi
Maximum working air pressure
100 psi
Air supply
75–100 psi
Air filter inlet size
3/8 npt(f)
Air filtration for air logic (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1–30.0:1
On-ratio accuracy
up to +/- 1%, user selectable
Fluids handled
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes
Fluid inlet sizes
1/4 npt(f)
Fluid outlet size (static mixer)
1/4 npt(f)
External power supply requirements
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
Operating temperature range
41–122°F
Approximate Weight
200 lb
Environmental conditions rating
indoor use, pollution degree (2), installation category II
Wetted parts
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
Fluid Flow Rate Range
G3000, G250 Meter
0.02–1.00 gpm
G3000HR, G250HR Meter
0.01–0.50 gpm
Coriolis Meter
0.005–1.00 gpm
S3000 Solvent Meter (accessory)
0.01–0.50 gpm
Noise Level
Sound pressure level
below 70 dBA
Sound power level
below 85 dBA
ProMix 2KE
Maximum fluid working pressure
See Manual 3A0868.
Maximum working air pressure
100 psi
Air supply
75 to 100 psi
Air filter inlet size
3/8 npt(f)
Air filtration for air logic (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1 to 30:1
Viscosity range of fluid
20 to 5000 cps
Fluid filtration (user-supplied)
100 mesh minimum
Fluid outlet size (static mixer)
1/4 npt(f)
External power supply requirements
85 – 250 Vac, 50/60 Hz, 2 amps maximum draw. 15 amp maximum circuit breaker required. 8 to 14 AWG power supply wire gauge
Operating temperature range
41° to 122°F
Approximate weight
300 lb
Environmental conditions rating
indoor use, pollution degree (2), installation category II
Fluids handled
one or two component:solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
On-ratio accuracy
1:1 to 10:1 Mixing Ratio
± 2%
10.1:1 to 30:1 Mixing Ratio
± 5%
Noise level
Sound pressure level
below 70 dBA
Sound power level
Below 85 dBA
Materials of construction
Wetted materials on all models
303, 304 SST; Tungsten carbide (with nickel binder);perfluoroelastomer; PTFE
ProMix 2KE Pump-Based System
Maximum fluid working pressure
See the ProMix 2KE manual.
Maximum working air pressure
100 psi
Air supply
75–100 psi
Air filter inlet size
3/8 npt(f)
Air filtration for air logic (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1–30:1
On-ratio accuracy
1:1 to 10:1 Mixing Ratios: +/- 2%, 10:1 to 30:1 Mixing Ratios: +/- 5%
Fluids handled
one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates
Viscosity range of fluid
20–5000 cps
Fluid filtration (user-supplied)
100 mesh minimum
Fluid outlet size (static mixer)
1/4 npt(f)
External power supply requirements
85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge
Operating temperature range
41–122°F
Approximate Weight
300 lb
Environmental conditions rating
indoor use, pollution degree (2), installation category II
Wetted parts
303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE
Noise Level
Sound pressure level
below 70 dBA
Sound power level
below 85 dBA
ProMix® 2KE
Maximum fluid working pressure
See Hazardous Location Models in manual 3A0870
Maximum working air pressure
100 psi
Air supply
75 – 100 psi
Air filter inlet size
3/8 npt(f)
Air filtration for air logic (Graco-supplied)
5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied)
30 micron (minimum) filtration required; clean and dry air
Mixing ratio range
0.1:1- 30:1
On-ratio accuracy
up to ±1%, user selectable
Fluids handled
one or two component:
solvent and waterborne paints
polyurethanes
epoxies
acid catalyzed varnishes
moisture sensitive isocyanates
Viscosity range of fluid
20- 5000 cps
Fluid filtration (user-supplied)
100 mesh minimum
Fluid flow rate range
G3000, G250 Meter
0.02-1.00 gal/min
G3000HR, G250HR Meter
0.01-0.50 gal/min
Coriolis Meter
0.005-1.00 gal/min
S3000 Solvent Meter (accessory)
0.01-0.50 gal/min
Fluid inlet sizes
Flow Meter
1/4 npt(f)
Dose Valve/Color Valve Adapters
1/4 npt(f)
Fluid outlet size (static mixer)
1/4 npt(f)
External Power Supply Requirements
85 15 amp maximum circuit breaker required-
250 Vac, 50/60 Hz, 2 amps maximum draw
8 to 14 AWG power supply wire gauge
Operating temperature range
41- 122° F
Approximate Weight
Meter Systems
200 lb
Pump Systems
300 lb
Environmental Conditions Rating
indoor use, pollution degree (2), installation category II
Noise Level
Sound pressure level
below 70 dBA
Sound power level
below 85 dBA
Wetted parts
303, 304 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE
Product Downloads
3A0868H – ProMix 2KE, Pump-Based Plural Component Proportioner, Operation Manual, English
3A0869J – ProMix 2KE, Meter-Based Plural Component Proportioner, Operation Manual, English
3A0870M, ProMix 2KE Plural Component Proportioner , Repair/Parts, English
3A1323C, ProMix 2KE Alternator Power Conversion Kit Instructions/Parts Manual, English
312781E, Fluid Mix Manifold Instruction-Parts Manual, English
3A1324B, ProMix 2KE Electric Power Conversion Kit Instructions/Parts Manual, English
3A1333A, ProMix 2KE USB Module Kit Instructions/Parts Manual, English
3A1325C, ProMix 2KE Stand Kits Instructions/Parts Manual, English
3A1332A, ProMix 2KE 3-Color Valve Stack Kit Instructions/Parts Manual, English
406713B, Dispense Valve Acid Kit, Instructions-Parts, English
406910A, Valve Stack Rebuild Kit for ProMix 2KE, Instructions/Parts, English
344876EN-C ProMix 2KE Brochure